Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_Chillers_Validation_Carnot_TEva_HighTemperature",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_Chillers_Validation_Carnot_TEva_HighTemperature",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.473/1.473, allocations: 251.9 MB / 266.9 MB, free: 11.02 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0015/0.0015, allocations: 181.2 kB / 326.5 MB, free: 2.246 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.245/2.245, allocations: 205.4 MB / 0.5775 GB, free: 20.24 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001003/0.001002, allocations: 105.4 kB / 0.6821 GB, free: 12.88 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0003811/0.0003811, allocations: 13.16 kB / 0.7963 GB, free: 135.1 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2824/0.2828, allocations: 106.3 MB / 0.9001 GB, free: 63.85 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.117/1.399, allocations: 414.9 MB / 1.305 GB, free: 1.457 MB / 0.8073 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002846/1.4, allocations: 91.52 kB / 1.305 GB, free: 1.41 MB / 0.8073 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Chillers/Examples/Carnot_TEva.mo:19:3-33:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature Notification: Performance of FrontEnd: time 0.1966/1.596, allocations: 82.76 MB / 1.386 GB, free: 10.45 MB / 0.8855 GB