Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Electrical_AC_ThreePhasesBalanced_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Electrical_AC_ThreePhasesBalanced_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.463/1.463, allocations: 251.9 MB / 266.9 MB, free: 11.04 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001139/0.001139, allocations: 188.7 kB / 326.5 MB, free: 2.242 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.977/1.977, allocations: 205.4 MB / 0.5775 GB, free: 20.51 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009184/0.0009184, allocations: 90.3 kB / 0.6821 GB, free: 13.35 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0003667/0.0003667, allocations: 15.67 kB / 0.7963 GB, free: 135.4 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2608/0.2611, allocations: 106.3 MB / 0.9002 GB, free: 64.37 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.887/6.148, allocations: 2.224 GB / 3.124 GB, free: 325.1 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004057/6.148, allocations: 107.7 kB / 3.124 GB, free: 325.1 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels Notification: Performance of FrontEnd: time 0.1676/6.316, allocations: 66.9 MB / 3.189 GB, free: 296.6 MB / 0.8855 GB