Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.IdealHeatingCoolingSummer.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.IdealHeatingCoolingSummer,fileNamePrefix="Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Examples_SmallOffice_IdealHeatingCoolingSummer",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.IdealHeatingCoolingSummer,fileNamePrefix="Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Examples_SmallOffice_IdealHeatingCoolingSummer",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.58/2.58, allocations: 390.3 MB / 405.3 MB, free: 13.45 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001444/0.001444, allocations: 185 kB / 498.1 MB, free: 5.723 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.942/1.942, allocations: 223.2 MB / 0.7948 GB, free: 17.93 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001121/0.00112, allocations: 106.9 kB / 0.9346 GB, free: 6.23 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.0005585/0.0005586, allocations: 8.062 kB / 1.084 GB, free: 221.4 MB / 0.823 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3825/0.3831, allocations: 142.3 MB / 1.223 GB, free: 114.2 MB / 0.823 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.325/5.708, allocations: 1.98 GB / 3.203 GB, free: 30.15 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003987/5.708, allocations: 109.2 kB / 3.203 GB, free: 30.04 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/ThermalZones/EnergyPlus_9_6_0/BaseClasses/ThermalZoneAdapter.mo:101:3-131:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.IdealHeatingCoolingSummer Notification: Performance of FrontEnd: time 7.32/13.03, allocations: 1.654 GB / 4.858 GB, free: 148.1 MB / 1.182 GB