Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.Guideline36Summer.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.Guideline36Summer,fileNamePrefix="Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Examples_SmallOffice_Guideline36Summer",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.Guideline36Summer,fileNamePrefix="Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Examples_SmallOffice_Guideline36Summer",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.475/2.475, allocations: 390.3 MB / 405.3 MB, free: 13.55 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001799/0.001799, allocations: 183.3 kB / 498.1 MB, free: 5.766 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.845/1.845, allocations: 223.2 MB / 0.7948 GB, free: 18 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001109/0.001109, allocations: 96.2 kB / 0.9346 GB, free: 6.289 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.0005166/0.0005167, allocations: 13.92 kB / 1.084 GB, free: 221.3 MB / 0.823 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3696/0.3701, allocations: 142.3 MB / 1.223 GB, free: 114.3 MB / 0.823 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.172/7.542, allocations: 2.443 GB / 3.666 GB, free: 7.168 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002708/7.543, allocations: 108.5 kB / 3.666 GB, free: 7.062 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/ThermalZones/EnergyPlus_9_6_0/BaseClasses/ThermalZoneAdapter.mo:101:3-131:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.Guideline36Summer Notification: Performance of FrontEnd: time 7.694/15.24, allocations: 1.722 GB / 5.388 GB, free: 78.36 MB / 1.198 GB