Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF,fileNamePrefix="Buildings_9_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case650FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF,fileNamePrefix="Buildings_9_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case650FF",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.439/2.439, allocations: 390.3 MB / 405.3 MB, free: 13.47 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001256/0.001256, allocations: 179.4 kB / 498.1 MB, free: 5.691 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.736/1.736, allocations: 223.2 MB / 0.7948 GB, free: 17.9 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001101/0.0011, allocations: 97.55 kB / 0.9346 GB, free: 6.207 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.0003987/0.0003988, allocations: 6.812 kB / 1.084 GB, free: 221.4 MB / 0.823 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3141/0.3146, allocations: 142.3 MB / 1.223 GB, free: 114.1 MB / 0.823 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.574/5.889, allocations: 2.095 GB / 3.318 GB, free: 303.3 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0005236/5.889, allocations: 124.9 kB / 3.318 GB, free: 303.3 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF Notification: Performance of FrontEnd: time 2.347/8.237, allocations: 0.6458 GB / 3.964 GB, free: 135.1 MB / 1.167 GB