Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer,fileNamePrefix="Buildings_9_Buildings_Applications_DataCenters_ChillerCooled_Examples_IntegratedPrimarySecondaryEconomizer",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer,fileNamePrefix="Buildings_9_Buildings_Applications_DataCenters_ChillerCooled_Examples_IntegratedPrimarySecondaryEconomizer",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.395/2.395, allocations: 390.3 MB / 405.3 MB, free: 13.45 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001237/0.001237, allocations: 195.1 kB / 498.1 MB, free: 5.676 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.697/1.697, allocations: 223.1 MB / 0.7948 GB, free: 18.86 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001111/0.001111, allocations: 107.8 kB / 0.9346 GB, free: 7.152 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.0003991/0.0003992, allocations: 10.78 kB / 1.084 GB, free: 212.7 MB / 0.8073 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3091/0.3095, allocations: 142.4 MB / 1.223 GB, free: 89.47 MB / 0.8073 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.711/7.02, allocations: 2.477 GB / 3.7 GB, free: 285 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004754/7.021, allocations: 109.2 kB / 3.7 GB, free: 285 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumCW[2].pressure.V_flow={0.006940000000000001, 0.02082, 0.0347, 0.04164}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumCW[1].pressure.V_flow={0.006940000000000001, 0.02082, 0.0347, 0.04164}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumPri[2].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumPri[1].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumSec[2].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumSec[1].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Applications/DataCenters/ChillerCooled/Examples/BaseClasses/PartialDataCenter.mo:121:5-121:17:writable] Error: Type mismatch in binding hydraulicEfficiency = Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency({0}, {0.7}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[1] V_flow; Real(max = 1.0, quantity = "Efficiency", unit = "1", min = 0.0)[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency Integer[1] V_flow; Real[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer Notification: Performance of FrontEnd: time 3.781/10.8, allocations: 1.145 GB / 4.845 GB, free: 78.05 MB / 1.167 GB