Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop,fileNamePrefix="Buildings_9_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_ClosedLoop",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop,fileNamePrefix="Buildings_9_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_ClosedLoop",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.246/2.246, allocations: 390.3 MB / 405.3 MB, free: 13.46 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001072/0.001072, allocations: 181 kB / 498.1 MB, free: 5.738 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.666/1.666, allocations: 223.2 MB / 0.7948 GB, free: 17.88 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008935/0.0008935, allocations: 96.33 kB / 0.9346 GB, free: 6.18 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.0003735/0.0003734, allocations: 11.03 kB / 1.084 GB, free: 221.4 MB / 0.823 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2612/0.2616, allocations: 142.3 MB / 1.223 GB, free: 114.1 MB / 0.823 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.55/5.812, allocations: 2.358 GB / 3.581 GB, free: 73.28 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003391/5.812, allocations: 113.1 kB / 3.581 GB, free: 73.21 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Applications/DataCenters/ChillerCooled/Equipment/Validation/CoolingCoilHumidifyingHeating_ClosedLoop.mo:9:22-9:46:writable] Error: Class Medium2 not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra.Medium. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Sensors/MassFractionTwoPort.mo:27:11-27:55:writable] Error: Variable Medium.substanceNames[1:Medium.nXi] not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Applications/DataCenters/ChillerCooled/Equipment/Validation/CoolingCoilHumidifyingHeating_ClosedLoop.mo:9:22-9:46:writable] Error: Class Medium2 not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra.Medium. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Sensors/MassFractionTwoPort.mo:26:3-28:103:writable] Error: Class Medium.MassFraction not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra while instantiating masFra.XiVec. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop Notification: Performance of FrontEnd: time 1.571/7.384, allocations: 385.1 MB / 3.957 GB, free: 161.7 MB / 1.167 GB