Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOutputVariable.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOutputVariable,fileNamePrefix="Buildings_8_Buildings_ThermalZones_EnergyPlus_Validation_OutputVariable_OneZoneOutputVariable",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOutputVariable,fileNamePrefix="Buildings_8_Buildings_ThermalZones_EnergyPlus_Validation_OutputVariable_OneZoneOutputVariable",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.71/1.71, allocations: 292.6 MB / 307.5 MB, free: 5.199 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001043/0.001043, allocations: 173.2 kB / 377.1 MB, free: 1.527 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.799/1.799, allocations: 205.4 MB / 0.6366 GB, free: 9.496 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009768/0.0009767, allocations: 93.23 kB / 0.7509 GB, free: 62.67 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0003522/0.0003521, allocations: 8 kB / 0.8749 GB, free: 11.24 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3209/0.3213, allocations: 116.3 MB / 0.9884 GB, free: 6.781 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.089/7.41, allocations: 2.075 GB / 3.064 GB, free: 106 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004573/7.411, allocations: 94.19 kB / 3.064 GB, free: 105.9 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/ThermalZones/EnergyPlus/OutputVariable.mo:39:3-69:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOutputVariable Notification: Performance of FrontEnd: time 0.09433/7.505, allocations: 35.36 MB / 3.098 GB, free: 71.92 MB / 0.948 GB