Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter,fileNamePrefix="Buildings_8_Buildings_ThermalZones_EnergyPlus_Examples_SmallOffice_IdealHeatingCoolingWinter",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter,fileNamePrefix="Buildings_8_Buildings_ThermalZones_EnergyPlus_Examples_SmallOffice_IdealHeatingCoolingWinter",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.999/1.999, allocations: 292.6 MB / 307.5 MB, free: 5.18 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001473/0.001473, allocations: 191.6 kB / 377.1 MB, free: 1.527 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.153/2.153, allocations: 205.4 MB / 0.6366 GB, free: 8.547 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009904/0.0009904, allocations: 91.25 kB / 0.7509 GB, free: 63 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004193/0.0004194, allocations: 8 kB / 0.8749 GB, free: 11.12 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.342/0.3425, allocations: 116.3 MB / 0.9884 GB, free: 6.664 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.237/7.58, allocations: 2.133 GB / 3.121 GB, free: 83.71 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003202/7.58, allocations: 105.4 kB / 3.122 GB, free: 83.61 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter Notification: Performance of FrontEnd: time 7.742/15.32, allocations: 1.632 GB / 4.754 GB, free: 96.29 MB / 0.9948 GB