Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,fileNamePrefix="Buildings_8_Buildings_Electrical_AC_ThreePhasesBalanced_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,fileNamePrefix="Buildings_8_Buildings_Electrical_AC_ThreePhasesBalanced_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.718/1.718, allocations: 292.6 MB / 307.5 MB, free: 5.207 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001202/0.001202, allocations: 184.9 kB / 377.1 MB, free: 1.531 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.818/1.818, allocations: 205.4 MB / 0.6366 GB, free: 8.543 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009303/0.0009302, allocations: 94.73 kB / 0.7509 GB, free: 63.13 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004067/0.0004067, allocations: 16 kB / 0.8749 GB, free: 11.07 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3065/0.3069, allocations: 116.3 MB / 0.9884 GB, free: 6.625 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.7/6.007, allocations: 2.106 GB / 3.095 GB, free: 111.2 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002894/6.007, allocations: 109.6 kB / 3.095 GB, free: 111.1 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels Notification: Performance of FrontEnd: time 0.1587/6.166, allocations: 66.88 MB / 3.16 GB, free: 44.25 MB / 0.948 GB