Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels,fileNamePrefix="Buildings_8_Buildings_Electrical_AC_OnePhase_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels,fileNamePrefix="Buildings_8_Buildings_Electrical_AC_OnePhase_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.805/1.805, allocations: 292.6 MB / 307.5 MB, free: 5.215 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001244/0.001244, allocations: 187.9 kB / 377.1 MB, free: 1.547 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.719/1.719, allocations: 205.4 MB / 0.6366 GB, free: 8.617 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00098/0.00098, allocations: 86.03 kB / 0.7509 GB, free: 62.86 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0003525/0.0003527, allocations: 15.98 kB / 0.8749 GB, free: 11.12 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2498/0.2502, allocations: 116.3 MB / 0.9884 GB, free: 6.664 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.48/5.731, allocations: 2.104 GB / 3.092 GB, free: 114.7 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003426/5.731, allocations: 109.1 kB / 3.092 GB, free: 114.6 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels Notification: Performance of FrontEnd: time 0.1627/5.894, allocations: 64.99 MB / 3.156 GB, free: 49.6 MB / 0.948 GB