Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel,fileNamePrefix="Buildings_8_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_PumpParallel",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel,fileNamePrefix="Buildings_8_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_PumpParallel",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.73/1.73, allocations: 292.6 MB / 307.5 MB, free: 5.203 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001347/0.001348, allocations: 180 kB / 377.1 MB, free: 1.531 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.881/1.881, allocations: 205.4 MB / 0.6366 GB, free: 8.605 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009187/0.0009187, allocations: 98.7 kB / 0.7509 GB, free: 62.91 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0003811/0.0003812, allocations: 8 kB / 0.8749 GB, free: 11.09 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3299/0.3303, allocations: 116.3 MB / 0.9884 GB, free: 6.637 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.93/2.26, allocations: 449.6 MB / 1.428 GB, free: 268.1 MB / 0.9323 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003484/2.261, allocations: 107.4 kB / 1.428 GB, free: 268.1 MB / 0.9323 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Applications/DataCenters/ChillerCooled/Equipment/BaseClasses/PartialPumpParallel.mo:101:11-101:18:writable] Error: Type mismatch in binding hydraulicEfficiency = Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency({0}, {0.7}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[1] V_flow; Real(max = 1.0, quantity = "Efficiency", unit = "1", min = 0.0)[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency Integer[1] V_flow; Real[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel Notification: Performance of FrontEnd: time 1.581/3.842, allocations: 467.5 MB / 1.884 GB, free: 167.7 MB / 0.9323 GB