Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOutputVariable.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOutputVariable,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_EnergyPlus_Validation_OutputVariable_OneZoneOutputVariable",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOutputVariable,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_EnergyPlus_Validation_OutputVariable_OneZoneOutputVariable",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.581/2.581, allocations: 287.3 MB / 302.3 MB, free: 8.262 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001615/0.001614, allocations: 184.9 kB / 370.8 MB, free: 10.84 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.041/2.041, allocations: 205.4 MB / 0.6295 GB, free: 10.61 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001247/0.001247, allocations: 96.48 kB / 0.7428 GB, free: 6.605 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0005065/0.0005066, allocations: 12.25 kB / 0.8657 GB, free: 140.2 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2403/0.2409, allocations: 115.3 MB / 0.9783 GB, free: 28.27 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.064/7.305, allocations: 2.074 GB / 3.053 GB, free: 200 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003395/7.305, allocations: 99.12 kB / 3.053 GB, free: 199.9 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/EnergyPlus/OutputVariable.mo:39:3-69:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOutputVariable Notification: Performance of FrontEnd: time 0.1373/7.443, allocations: 35.67 MB / 3.088 GB, free: 169.8 MB / 0.948 GB