Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_EnergyPlus_Examples_SmallOffice_IdealHeatingCoolingWinter",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_EnergyPlus_Examples_SmallOffice_IdealHeatingCoolingWinter",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.563/2.563, allocations: 287.3 MB / 302.3 MB, free: 8.312 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001596/0.001596, allocations: 171.2 kB / 370.8 MB, free: 10.86 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.25/2.25, allocations: 205.4 MB / 0.6295 GB, free: 10.62 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00119/0.00119, allocations: 100.1 kB / 0.7428 GB, free: 6.621 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.000498/0.0004979, allocations: 10.56 kB / 0.8657 GB, free: 140.5 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2374/0.238, allocations: 115.3 MB / 0.9783 GB, free: 28.32 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.109/7.347, allocations: 2.132 GB / 3.11 GB, free: 121.4 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004073/7.348, allocations: 105.7 kB / 3.11 GB, free: 121.4 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter Notification: Performance of FrontEnd: time 9.177/16.52, allocations: 1.633 GB / 4.743 GB, free: 116.5 MB / 0.9948 GB