Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop,fileNamePrefix="Buildings_8_0_0_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_ClosedLoop",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop,fileNamePrefix="Buildings_8_0_0_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_ClosedLoop",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.482/2.482, allocations: 287.3 MB / 302.3 MB, free: 8.273 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001466/0.001466, allocations: 182.9 kB / 370.8 MB, free: 10.88 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.069/2.069, allocations: 205.4 MB / 0.6295 GB, free: 10.65 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001128/0.001128, allocations: 97.73 kB / 0.7428 GB, free: 6.66 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0005861/0.0005862, allocations: 12.42 kB / 0.8657 GB, free: 140.4 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2214/0.2221, allocations: 115.3 MB / 0.9783 GB, free: 28.33 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.758/7.98, allocations: 2.446 GB / 3.424 GB, free: 167.3 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004132/7.981, allocations: 123 kB / 3.424 GB, free: 167.2 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Applications/DataCenters/ChillerCooled/Equipment/Validation/CoolingCoilHumidifyingHeating_ClosedLoop.mo:9:22-9:46:writable] Error: Class Medium2 not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra.Medium. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Fluid/Sensors/MassFractionTwoPort.mo:27:11-27:55:writable] Error: Variable Medium.substanceNames[1:Medium.nXi] not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Applications/DataCenters/ChillerCooled/Equipment/Validation/CoolingCoilHumidifyingHeating_ClosedLoop.mo:9:22-9:46:writable] Error: Class Medium2 not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra.Medium. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Fluid/Sensors/MassFractionTwoPort.mo:26:3-28:103:writable] Error: Class Medium.MassFraction not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra while instantiating masFra.XiVec. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop Notification: Performance of FrontEnd: time 1.892/9.873, allocations: 380.4 MB / 3.795 GB, free: 168.8 MB / 0.948 GB