Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowInteriorShade.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowInteriorShade,fileNamePrefix="Buildings_7_0_0_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallWithWindowInteriorShade",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.225/2.225, allocations: 251 MB / 265.9 MB, free: 11.7 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001536/0.001536, allocations: 184.7 kB / 325.5 MB, free: 2.922 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.402/2.402, allocations: 205.4 MB / 0.5764 GB, free: 21.22 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00207/0.00207, allocations: 96.83 kB / 0.6809 GB, free: 14.09 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004945/0.0004942, allocations: 20.7 kB / 0.7951 GB, free: 135.8 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.237/0.2376, allocations: 106.3 MB / 0.8988 GB, free: 65.96 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.462/7.699, allocations: 2.333 GB / 3.231 GB, free: 180 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004033/7.7, allocations: 113 kB / 3.232 GB, free: 179.9 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowInteriorShade Notification: Performance of FrontEnd: time 2.536/10.24, allocations: 464.5 MB / 3.685 GB, free: 78.5 MB / 0.8855 GB