Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow,fileNamePrefix="Buildings_7_0_0_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.138/2.138, allocations: 251 MB / 265.9 MB, free: 11.68 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001541/0.001541, allocations: 175.4 kB / 325.5 MB, free: 2.891 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.417/2.417, allocations: 205.4 MB / 0.5764 GB, free: 20.8 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001218/0.001218, allocations: 97.25 kB / 0.6809 GB, free: 13.64 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004814/0.0004814, allocations: 12.5 kB / 0.7951 GB, free: 135.5 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2307/0.2312, allocations: 106.3 MB / 0.8988 GB, free: 65.45 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.598/7.829, allocations: 2.332 GB / 3.231 GB, free: 177.6 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000355/7.829, allocations: 112.3 kB / 3.231 GB, free: 177.5 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow Notification: Performance of FrontEnd: time 1.619/9.448, allocations: 235.5 MB / 3.461 GB, free: 207.3 MB / 0.8855 GB