Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.BaseClasses.Examples.MixedAirHeatMassBalance.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.BaseClasses.Examples.MixedAirHeatMassBalance,fileNamePrefix="Buildings_7_0_0_Buildings_ThermalZones_Detailed_BaseClasses_Examples_MixedAirHeatMassBalance",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.201/2.201, allocations: 251 MB / 265.9 MB, free: 11.72 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001554/0.001553, allocations: 184 kB / 325.5 MB, free: 2.91 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.36/2.36, allocations: 205.4 MB / 0.5764 GB, free: 21.18 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001153/0.001153, allocations: 107.8 kB / 0.6809 GB, free: 14.07 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004954/0.0004958, allocations: 11.59 kB / 0.795 GB, free: 135.7 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2247/0.2252, allocations: 106.3 MB / 0.8988 GB, free: 65.96 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.368/7.593, allocations: 2.209 GB / 3.108 GB, free: 244.2 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003725/7.594, allocations: 110.8 kB / 3.108 GB, free: 244.2 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/BaseClasses/Examples/MixedAirHeatMassBalance.mo:16:11-16:36:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.BaseClasses.Examples.MixedAirHeatMassBalance Notification: Performance of FrontEnd: time 0.5778/8.171, allocations: 170.1 MB / 3.274 GB, free: 156.6 MB / 0.8855 GB