Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.HeatPumps.Validation.ReciprocatingWaterToWater_Static.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.ReciprocatingWaterToWater_Static,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.212/2.212, allocations: 251 MB / 265.9 MB, free: 11.69 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001726/0.001726, allocations: 180.8 kB / 325.5 MB, free: 2.895 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.505/2.505, allocations: 205.4 MB / 0.5764 GB, free: 20.82 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001174/0.001173, allocations: 91.48 kB / 0.6809 GB, free: 13.68 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004954/0.0004952, allocations: 15.42 kB / 0.795 GB, free: 135.5 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.241/0.2416, allocations: 106.3 MB / 0.8988 GB, free: 65.51 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.402/1.643, allocations: 415 MB / 1.304 GB, free: 4.348 MB / 0.8073 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0005746/1.644, allocations: 95.33 kB / 1.304 GB, free: 4.301 MB / 0.8073 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/specificIsobaricHeatCapacityVap_Tv.mo:42:3-42:35:writable] Error: Variable A not found in scope Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/isentropicExponentVap_Tv.mo:20:3-20:84:writable] Error: Class Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope Buildings.Fluid.HeatPumps.Compressors.ReciprocatingCompressor$heaPum$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.ReciprocatingWaterToWater_Static Notification: Performance of FrontEnd: time 1.149/2.793, allocations: 118.9 MB / 1.42 GB, free: 293.8 MB / 0.8855 GB