Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.HeatPumps.Compressors.Validation.ReciprocatingCompressor.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Compressors.Validation.ReciprocatingCompressor,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_HeatPumps_Compressors_Validation_ReciprocatingCompressor",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.133/2.133, allocations: 251 MB / 265.9 MB, free: 11.67 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001647/0.001647, allocations: 187.3 kB / 325.5 MB, free: 2.898 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.408/2.408, allocations: 205.4 MB / 0.5764 GB, free: 20.79 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001186/0.001186, allocations: 104.9 kB / 0.6809 GB, free: 13.67 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0005053/0.0005052, allocations: 11.66 kB / 0.795 GB, free: 135.4 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2262/0.2267, allocations: 106.3 MB / 0.8988 GB, free: 65.49 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.2445/0.4713, allocations: 138.7 MB / 1.034 GB, free: 6.645 MB / 0.6823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003223/0.4717, allocations: 87.94 kB / 1.034 GB, free: 6.559 MB / 0.6823 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/specificIsobaricHeatCapacityVap_Tv.mo:42:3-42:35:writable] Error: Variable A not found in scope Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/isentropicExponentVap_Tv.mo:20:3-20:84:writable] Error: Class Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope Buildings.Fluid.HeatPumps.Compressors.ReciprocatingCompressor$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Compressors.Validation.ReciprocatingCompressor Notification: Performance of FrontEnd: time 0.02426/0.4959, allocations: 5.448 MB / 1.04 GB, free: 1.098 MB / 0.6823 GB