Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_Chillers_Validation_CarnotVerifyEtaCarnot",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.117/2.117, allocations: 251 MB / 265.9 MB, free: 11.69 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001542/0.001542, allocations: 176.7 kB / 325.5 MB, free: 2.906 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.346/2.346, allocations: 205.4 MB / 0.5764 GB, free: 20.79 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001168/0.001168, allocations: 98.92 kB / 0.6809 GB, free: 13.67 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.000634/0.0006342, allocations: 11.66 kB / 0.795 GB, free: 135.5 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2679/0.2686, allocations: 106.3 MB / 0.8988 GB, free: 65.5 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.299/1.567, allocations: 417.4 MB / 1.306 GB, free: 1.363 MB / 0.8073 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003686/1.568, allocations: 96.11 kB / 1.306 GB, free: 1.312 MB / 0.8073 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Chillers/Validation/CarnotVerifyEtaCarnot.mo:53:3-71:69:writable] Error: Variable chi_TEva: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi_TEva: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.CarnotVerifyEtaCarnot Notification: Performance of FrontEnd: time 1.199/2.767, allocations: 149.6 MB / 1.453 GB, free: 294 MB / 0.8855 GB