Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallNoWindow.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallNoWindow,fileNamePrefix="Buildings_6_0_0_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_OnlyExteriorWallNoWindow",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.01116/0.01116, allocations: 108.8 kB / 15.05 MB, free: 5.93 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001169/0.001169, allocations: 186.8 kB / 15.95 MB, free: 5.895 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 2.093/2.093, allocations: 194.6 MB / 211.3 MB, free: 11.02 MB / 170.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 2.271/2.271, allocations: 236.1 MB / 492.6 MB, free: 11.26 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0004997/0.0004999, allocations: 16 kB / 0.587 GB, free: 2.066 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7154/0.716, allocations: 98.71 MB / 0.6834 GB, free: 16.71 MB / 0.5261 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.573/8.289, allocations: 2.317 GB / 3 GB, free: 71.8 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003633/8.29, allocations: 95.83 kB / 3 GB, free: 71.75 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallNoWindow Notification: Performance of FrontEnd: time 1.678/9.968, allocations: 240.8 MB / 3.235 GB, free: 162.2 MB / 0.823 GB