Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.MixingVolumes.Validation.MixingVolumeTraceSubstanceReverseFlowPrescribedHeatFlowRate.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.MixingVolumes.Validation.MixingVolumeTraceSubstanceReverseFlowPrescribedHeatFlowRate,fileNamePrefix="Buildings_6_0_0_Buildings_Fluid_MixingVolumes_Validation_MixingVolumeTraceSubstanceReverseFlowPrescribedHeatFlowRate",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.0114/0.0114, allocations: 106.6 kB / 15.05 MB, free: 5.93 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001189/0.001189, allocations: 186.4 kB / 15.94 MB, free: 5.895 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 2.038/2.038, allocations: 194.6 MB / 211.3 MB, free: 11.06 MB / 170.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 2.264/2.264, allocations: 236.1 MB / 492.6 MB, free: 11.37 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0006722/0.0006723, allocations: 19.98 kB / 0.587 GB, free: 2.07 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7362/0.7369, allocations: 98.72 MB / 0.6834 GB, free: 16.65 MB / 0.5261 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.037/7.773, allocations: 2.179 GB / 2.863 GB, free: 212.7 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000323/7.774, allocations: 91.39 kB / 2.863 GB, free: 212.6 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/MixingVolumes/Validation/MixingVolumeTraceSubstanceReverseFlow.mo:10:9-10:18:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/PartialSource_Xi_C.mo:19:3-22:89:writable] Error: Array dimension mismatch, expression {0.003} has type Real[1], expected array dimensions [0]. Error: Error occurred while flattening model Buildings.Fluid.MixingVolumes.Validation.MixingVolumeTraceSubstanceReverseFlowPrescribedHeatFlowRate Notification: Performance of FrontEnd: time 0.1206/7.894, allocations: 37.84 MB / 2.9 GB, free: 181.1 MB / 0.823 GB