Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.HeatPumps.Validation.ReciprocatingWaterToWater_Static.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.ReciprocatingWaterToWater_Static,fileNamePrefix="Buildings_6_0_0_Buildings_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.01689/0.01689, allocations: 107.5 kB / 15.05 MB, free: 5.934 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.002032/0.002032, allocations: 183.9 kB / 15.95 MB, free: 5.898 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 2.247/2.247, allocations: 194.5 MB / 211.2 MB, free: 11.07 MB / 170.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 2.403/2.403, allocations: 236.1 MB / 492.6 MB, free: 11.34 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0005379/0.0005379, allocations: 12 kB / 0.587 GB, free: 2.066 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7503/0.7509, allocations: 98.72 MB / 0.6834 GB, free: 16.87 MB / 0.5261 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.26/2.01, allocations: 406.5 MB / 1.08 GB, free: 43.01 MB / 0.7292 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003059/2.011, allocations: 91.77 kB / 1.08 GB, free: 42.96 MB / 0.7292 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Media/Refrigerants/R410A/specificIsobaricHeatCapacityVap_Tv.mo:42:3-42:35:writable] Error: Variable A not found in scope Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Media/Refrigerants/R410A/isentropicExponentVap_Tv.mo:20:3-20:84:writable] Error: Class Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope Buildings.Fluid.HeatPumps.Compressors.ReciprocatingCompressor$heaPum$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.ReciprocatingWaterToWater_Static Notification: Performance of FrontEnd: time 0.3937/2.404, allocations: 116.7 MB / 1.194 GB, free: 15.52 MB / 0.8073 GB