Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.Examples.Borefields.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.Examples.Borefields,fileNamePrefix="Buildings_6_0_0_Buildings_Fluid_Geothermal_Borefields_Examples_Borefields",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.01733/0.01733, allocations: 109.7 kB / 15.05 MB, free: 5.934 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001868/0.001867, allocations: 183.3 kB / 15.94 MB, free: 5.898 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 2.091/2.091, allocations: 194.5 MB / 211.2 MB, free: 11.07 MB / 170.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 2.186/2.186, allocations: 236.1 MB / 492.6 MB, free: 11.4 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.000479/0.0004791, allocations: 12 kB / 0.587 GB, free: 2.098 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6864/0.6869, allocations: 98.72 MB / 0.6834 GB, free: 16.71 MB / 0.5261 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.304/1.991, allocations: 0.4911 GB / 1.174 GB, free: 15.17 MB / 0.7917 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003723/1.991, allocations: 110.3 kB / 1.175 GB, free: 15.11 MB / 0.7917 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Geothermal/Borefields/Examples/Borefields.mo:98:5-98:28:writable] Error: Component borFieUTub.borFieDat of variability PARAM has binding borFieUTubDat of higher variability VAR. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.Examples.Borefields Notification: Performance of FrontEnd: time 0.8944/2.886, allocations: 87.18 MB / 1.26 GB, free: 259.7 MB / 0.823 GB