Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.IBPSA.Fluid.FixedResistances.Validation.PlugFlowPipes.FlowReversal.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package BuildSysPro with version 3.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo) Running command: "" <> buildModelFMU(BuildSysPro.IBPSA.Fluid.FixedResistances.Validation.PlugFlowPipes.FlowReversal,fileNamePrefix="BuildSysPro_BuildSysPro_IBPSA_Fluid_FixedResistances_Validation_PlugFlowPipes_FlowReversal",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildSysPro.IBPSA.Fluid.FixedResistances.Validation.PlugFlowPipes.FlowReversal,fileNamePrefix="BuildSysPro_BuildSysPro_IBPSA_Fluid_FixedResistances_Validation_PlugFlowPipes_FlowReversal",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo): time 0.7155/0.7155, allocations: 128.7 MB / 143.7 MB, free: 2.316 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001149/0.001149, allocations: 185.6 kB / 173.7 MB, free: 6.125 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.516/1.516, allocations: 205.4 MB / 409 MB, free: 10.5 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009279/0.0009279, allocations: 93.41 kB / 486.6 MB, free: 13 MB / 378.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003014/0.0003014, allocations: 12.02 kB / 0.5604 GB, free: 97.57 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1402/0.1405, allocations: 76.77 MB / 0.6354 GB, free: 30.45 MB / 442.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 1.21/1.35, allocations: 401.1 MB / 1.027 GB, free: 169.6 MB / 0.6511 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002932/1.351, allocations: 106.9 kB / 1.027 GB, free: 169.6 MB / 0.6511 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/IBPSA/Fluid/FixedResistances/BaseClasses/PlugFlowTransportDelay.mo:49:3-55:44:writable] Error: Function argument initialValues={time + t_in_start, time + t_out_start} in call to spatialDistribution has variability continuous which is not a parameter expression. Error: Error occurred while flattening model BuildSysPro.IBPSA.Fluid.FixedResistances.Validation.PlugFlowPipes.FlowReversal Notification: Performance of FrontEnd: time 0.9576/2.308, allocations: 258.2 MB / 1.279 GB, free: 149.5 MB / 0.6511 GB