Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr AixLib_AixLib.Systems.HydraulicModules.Example.Pump.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo", uses=false) Using package SDF with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo) Using package Modelica_DeviceDrivers with version 2.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package AixLib with version 1.3.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/package.mo) Running command: "" <> buildModelFMU(AixLib.Systems.HydraulicModules.Example.Pump,fileNamePrefix="AixLib_AixLib_Systems_HydraulicModules_Example_Pump",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(AixLib.Systems.HydraulicModules.Example.Pump,fileNamePrefix="AixLib_AixLib_Systems_HydraulicModules_Example_Pump",fmuType="me",version="2.0",platforms={"static"}) [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:6228:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:6853:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:8435:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:9369:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:11505:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:12875:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/ThermalZones/HighOrder/Components/Examples/DryAir/DryAir_test.mo:71:18-71:405:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/ThermalZones/HighOrder/Components/DryAir/InfiltrationRate_DIN12831.mo:20:192-20:2066:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/ThermalZones/HighOrder/Components/DryAir/InfiltrationRate_DIN12831.mo:20:192-20:4252:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_N_E_S_W_RoofN_Roof_S.mo:5:35-5:362:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_N_E_S_W_Hor.mo:5:35-5:320:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_NE_SE_SW_NW_Hor.mo:5:35-5:324:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/CHP/CHPDataSimple/CHP_XRGI_9kWel.mo:25:34-25:588:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/CHP/CHPDataSimple/CHP_XRGI_9kWel.mo:25:34-25:3852:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/CHP/CHPDataSimple/CHP_Cleanergy_C9G.mo:36:34-36:594:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/BoundaryConditions/InternalGains/Examples/InternalGains/Machines.mo:31:20-31:400:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/BoundaryConditions/InternalGains/Examples/InternalGains/Lights.mo:27:20-27:398:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/package.mo): time 1.761/1.761, allocations: 267.3 MB / 282.2 MB, free: 5.309 MB / 234.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001307/0.001307, allocations: 187.2 kB / 339.9 MB, free: 2.586 MB / 266.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.521/1.521, allocations: 223.1 MB / 0.6061 GB, free: 1.777 MB / 474.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009843/0.0009843, allocations: 93.23 kB / 0.7116 GB, free: 6.375 MB / 490.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo): time 0.5208/0.5208, allocations: 12.02 MB / 0.8287 GB, free: 67.22 MB / 0.5887 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo:9:42-9:258:writable] Notification: This is an open source dummy package of a commercial library. If you want it to be supported, you will need to add an implemention on our github repository: https://github.com/Modelica-OpenVendorSpecificLibraries. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo): time 0.0004854/0.0004854, allocations: 11.92 kB / 0.937 GB, free: 13.99 MB / 0.5887 GB Notification: AixLib requested package SDF of version 0.4.2. SDF 0.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.0006852/0.0006854, allocations: 20 kB / 1.058 GB, free: 2.465 MB / 0.698 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6798/0.6805, allocations: 110.2 MB / 1.165 GB, free: 160 MB / 0.7449 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.147/1.828, allocations: 464.6 MB / 1.619 GB, free: 21.53 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002401/1.828, allocations: 93.06 kB / 1.619 GB, free: 21.48 MB / 0.823 GB Notification: Performance of FrontEnd - DAE generated: time 8.623/10.45, allocations: 2.098 GB / 3.717 GB, free: 83.02 MB / 1.042 GB Notification: Performance of FrontEnd: time 3.046e-06/10.45, allocations: 0 / 3.717 GB, free: 83.02 MB / 1.042 GB Notification: Performance of Transformations before backend: time 0.001393/10.45, allocations: 147.9 kB / 3.717 GB, free: 83 MB / 1.042 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 912 * Number of variables: 912 Notification: Performance of Generate backend data structure: time 0.03083/10.48, allocations: 7.659 MB / 3.725 GB, free: 79.94 MB / 1.042 GB Notification: Performance of prepare preOptimizeDAE: time 5.327e-05/10.48, allocations: 11.56 kB / 3.725 GB, free: 79.94 MB / 1.042 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.002762/10.49, allocations: 488 kB / 3.725 GB, free: 79.88 MB / 1.042 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.005618/10.49, allocations: 0.7746 MB / 3.726 GB, free: 79.54 MB / 1.042 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.03798/10.53, allocations: 13.35 MB / 3.739 GB, free: 78.46 MB / 1.042 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0004255/10.53, allocations: 278.3 kB / 3.739 GB, free: 78.46 MB / 1.042 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.001921/10.53, allocations: 382 kB / 3.74 GB, free: 78.45 MB / 1.042 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.01241/10.54, allocations: 4.358 MB / 3.744 GB, free: 77.96 MB / 1.042 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0001093/10.54, allocations: 12.3 kB / 3.744 GB, free: 77.95 MB / 1.042 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0004575/10.55, allocations: 153.4 kB / 3.744 GB, free: 77.95 MB / 1.042 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.000132/10.55, allocations: 136 kB / 3.744 GB, free: 77.95 MB / 1.042 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.006612/10.55, allocations: 3.322 MB / 3.747 GB, free: 77.91 MB / 1.042 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.03941/10.59, allocations: 24.77 MB / 3.772 GB, free: 67.38 MB / 1.042 GB Notification: Performance of preOpt comSubExp (simulation): time 0.004916/10.6, allocations: 2.207 MB / 3.774 GB, free: 67.32 MB / 1.042 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt evalFunc (simulation): time 0.0201/10.62, allocations: 10.66 MB / 3.784 GB, free: 61.64 MB / 1.042 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 4.683e-05/10.62, allocations: 63.22 kB / 3.784 GB, free: 61.59 MB / 1.042 GB Notification: Performance of preOpt simplifyInStream (simulation): time 0.003385/10.62, allocations: 335.8 kB / 3.785 GB, free: 61.48 MB / 1.042 GB Notification: Performance of pre-optimization done (n=216): time 6.061e-06/10.62, allocations: 0 / 3.785 GB, free: 61.48 MB / 1.042 GB Notification: Performance of matching and sorting (n=216): time 0.01444/10.63, allocations: 5.65 MB / 3.79 GB, free: 59.81 MB / 1.042 GB Notification: Performance of inlineWhenForInitialization (initialization): time 4.973e-05/10.63, allocations: 73.25 kB / 3.79 GB, free: 59.75 MB / 1.042 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.01126/10.65, allocations: 4.871 MB / 3.795 GB, free: 59.44 MB / 1.042 GB Notification: Performance of collectPreVariables (initialization): time 0.0009366/10.65, allocations: 72.86 kB / 3.795 GB, free: 59.41 MB / 1.042 GB Notification: Performance of collectInitialEqns (initialization): time 0.002913/10.65, allocations: 2.572 MB / 3.797 GB, free: 58.69 MB / 1.042 GB Notification: Performance of collectInitialBindings (initialization): time 0.001593/10.65, allocations: 0.7741 MB / 3.798 GB, free: 58.19 MB / 1.042 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.000177/10.65, allocations: 52.09 kB / 3.798 GB, free: 58.19 MB / 1.042 GB Notification: Performance of setup shared object (initialization): time 0.0002373/10.65, allocations: 421.5 kB / 3.799 GB, free: 57.88 MB / 1.042 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.002562/10.65, allocations: 1.038 MB / 3.8 GB, free: 57.87 MB / 1.042 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.002916/10.66, allocations: 1.853 MB / 3.801 GB, free: 56.94 MB / 1.042 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.002762/10.66, allocations: 1.356 MB / 3.803 GB, free: 56.89 MB / 1.042 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 1.861e-05/10.66, allocations: 6.344 kB / 3.803 GB, free: 56.89 MB / 1.042 GB Notification: Performance of matching and sorting (n=359) (initialization): time 0.009869/10.67, allocations: 4.043 MB / 3.807 GB, free: 56.46 MB / 1.042 GB Notification: Performance of prepare postOptimizeDAE: time 0.002175/10.67, allocations: 10.42 MB / 3.817 GB, free: 45.62 MB / 1.042 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 5.788e-05/10.67, allocations: 30.25 kB / 3.817 GB, free: 45.62 MB / 1.042 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.003395/10.68, allocations: 0.8089 MB / 3.818 GB, free: 45.57 MB / 1.042 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.002295/10.68, allocations: 0.577 MB / 3.818 GB, free: 45.57 MB / 1.042 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.005249/10.68, allocations: 7.438 MB / 3.826 GB, free: 39.62 MB / 1.042 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.006183/10.69, allocations: 332.3 kB / 3.826 GB, free: 39.59 MB / 1.042 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.000682/10.69, allocations: 175.6 kB / 3.826 GB, free: 39.59 MB / 1.042 GB Notification: Performance of prepare postOptimizeDAE: time 1.383e-05/10.69, allocations: 3.562 kB / 3.826 GB, free: 39.59 MB / 1.042 GB Notification: Performance of postOpt replaceHomotopyWithSimplified (initialization): time 0.00866/10.7, allocations: 3.748 MB / 3.83 GB, free: 39.44 MB / 1.042 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 8.135e-05/10.7, allocations: 32.73 kB / 3.83 GB, free: 39.44 MB / 1.042 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.003737/10.7, allocations: 0.9772 MB / 3.831 GB, free: 39.38 MB / 1.042 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.002221/10.7, allocations: 0.5792 MB / 3.831 GB, free: 39.38 MB / 1.042 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.01236/10.72, allocations: 11.67 MB / 3.843 GB, free: 32.17 MB / 1.042 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.006446/10.72, allocations: 324.4 kB / 3.843 GB, free: 32.14 MB / 1.042 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.000763/10.72, allocations: 162.8 kB / 3.843 GB, free: 32.14 MB / 1.042 GB Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 98 * Number of states: 0 () * Number of discrete variables: 0 () * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (312): * Single equations (assignments): 298 * Array equations: 1 * Algorithm blocks: 0 * Record equations: 6 * When equations: 0 * If-equations: 0 * Equation systems (linear and non-linear blocks): 0 * Torn equation systems: 7 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 3 {(1,100.0%) 2,(1,100.0%) 2,(1,100.0%) 2} * Non-linear torn systems: 4 {1 5,1 5,1 5,1 11} Notification: Performance of prepare postOptimizeDAE: time 0.004912/10.73, allocations: 1.451 MB / 3.845 GB, free: 31.94 MB / 1.042 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.002282/10.73, allocations: 0.4885 MB / 3.845 GB, free: 31.68 MB / 1.042 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.01164/10.74, allocations: 4.376 MB / 3.849 GB, free: 31.34 MB / 1.042 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 6.886e-05/10.74, allocations: 37.94 kB / 3.849 GB, free: 31.34 MB / 1.042 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 2.303e-05/10.74, allocations: 5.219 kB / 3.849 GB, free: 31.34 MB / 1.042 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.006572/10.75, allocations: 3.181 MB / 3.852 GB, free: 31 MB / 1.042 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.02393/10.77, allocations: 10.08 MB / 3.862 GB, free: 29.89 MB / 1.042 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 3.792e-05/10.77, allocations: 9.188 kB / 3.862 GB, free: 29.89 MB / 1.042 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.001652/10.78, allocations: 386.6 kB / 3.863 GB, free: 29.89 MB / 1.042 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.002351/10.78, allocations: 0.6297 MB / 3.863 GB, free: 29.83 MB / 1.042 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0002143/10.78, allocations: 81.08 kB / 3.863 GB, free: 29.83 MB / 1.042 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.004401/10.78, allocations: 7.078 MB / 3.87 GB, free: 23.97 MB / 1.042 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 2.925e-06/10.78, allocations: 3.781 kB / 3.87 GB, free: 23.97 MB / 1.042 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.01067/10.79, allocations: 5.565 MB / 3.876 GB, free: 23.12 MB / 1.042 GB Notification: Performance of postOpt removeConstants (simulation): time 0.004345/10.8, allocations: 1.23 MB / 3.877 GB, free: 22.73 MB / 1.042 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.001769/10.8, allocations: 53 kB / 3.877 GB, free: 22.73 MB / 1.042 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.004251/10.8, allocations: 286.8 kB / 3.877 GB, free: 22.72 MB / 1.042 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0003401/10.8, allocations: 175.8 kB / 3.877 GB, free: 22.71 MB / 1.042 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0003089/10.8, allocations: 122.7 kB / 3.878 GB, free: 22.71 MB / 1.042 GB Notification: Performance of sorting global known variables: time 0.0076/10.81, allocations: 3.77 MB / 3.881 GB, free: 22.53 MB / 1.042 GB Notification: Performance of sort global known variables: time 4e-07/10.81, allocations: 0 / 3.881 GB, free: 22.53 MB / 1.042 GB Notification: Performance of remove unused functions: time 0.01765/10.83, allocations: 3.443 MB / 3.885 GB, free: 22.01 MB / 1.042 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 5 * Number of states: 26 (Unmixed.senT_a1.T,Unmixed.senT_a2.T,Unmixed.senT_b1.T,Unmixed.senT_b2.T,Unmixed.PT1_b2.y,Unmixed.PT1_b1.y,Unmixed.PT1_a1.y,Unmixed.PT1_a2.y,Unmixed.PumpInterface.pump.vol.dynBal.U,Unmixed.PumpInterface.pump.filter.s[1],Unmixed.PumpInterface.pump.filter.s[2],Unmixed.pipe1.plugFlowPipe.del.x,Unmixed.pipe1.plugFlowPipe.timDel.x,Unmixed.pipe1.plugFlowPipe.vol_b.dynBal.U,Unmixed.pipe1.plugFlowPipe.vol_a.dynBal.U,Unmixed.pipe1.Insulation.CylindricLoad1.heatCapacitor.T,Unmixed.pipe2.plugFlowPipe.del.x,Unmixed.pipe2.plugFlowPipe.timDel.x,Unmixed.pipe2.plugFlowPipe.vol_b.dynBal.U,Unmixed.pipe2.plugFlowPipe.vol_a.dynBal.U,Unmixed.pipe2.Insulation.CylindricLoad1.heatCapacitor.T,Unmixed.pipe3.plugFlowPipe.del.x,Unmixed.pipe3.plugFlowPipe.timDel.x,Unmixed.pipe3.plugFlowPipe.vol_b.dynBal.U,Unmixed.pipe3.plugFlowPipe.vol_a.dynBal.U,Unmixed.pipe3.Insulation.CylindricLoad1.heatCapacitor.T) * Number of discrete variables: 0 () * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (227): * Single equations (assignments): 184 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 36 * When equations: 0 * If-equations: 0 * Equation systems (linear and non-linear blocks): 0 * Torn equation systems: 7 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 3 {(1,100.0%) 2,(1,100.0%) 2,(1,100.0%) 2} * Non-linear torn systems: 4 {1 7,1 7,1 7,1 11} Notification: Performance of Backend phase and start with SimCode phase: time 0.01978/10.85, allocations: 9.474 MB / 3.894 GB, free: 19.37 MB / 1.042 GB Notification: Performance of simCode: created initialization part: time 0.01177/10.86, allocations: 5.778 MB / 3.899 GB, free: 18.09 MB / 1.042 GB Notification: Performance of simCode: created event and clocks part: time 9.347e-06/10.86, allocations: 0 / 3.899 GB, free: 18.09 MB / 1.042 GB Notification: Performance of simCode: created simulation system equations: time 0.003975/10.87, allocations: 2.014 MB / 3.901 GB, free: 17.53 MB / 1.042 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.0158/10.88, allocations: 2.639 MB / 3.904 GB, free: 17.39 MB / 1.042 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.04525/10.93, allocations: 30.56 MB / 3.934 GB, free: 10.02 MB / 1.057 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.005916/10.93, allocations: 3.016 MB / 3.937 GB, free: 9.16 MB / 1.057 GB Notification: Performance of simCode: alias equations: time 0.008265/10.94, allocations: 1.249 MB / 3.938 GB, free: 8.949 MB / 1.057 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.005652/10.95, allocations: 2.497 MB / 3.94 GB, free: 8.938 MB / 1.057 GB Notification: Performance of SimCode: time 1.522e-06/10.95, allocations: 0 / 3.94 GB, free: 8.938 MB / 1.057 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 1.033/11.98, allocations: 193.9 MB / 4.13 GB, free: 96.45 MB / 1.073 GB Notification: Performance of buildModelFMU: configured platform static using cached values: time 0.00017/11.98, allocations: 232.8 kB / 4.13 GB, free: 96.22 MB / 1.073 GB Error: Error building simulator. Build log: clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:7: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1240:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[350] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[19] /* Unmixed.pipe3.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe3.plugFlowPipe.timDel.u) */, tmp18, tmp19, tmp20 ,&data->localData[0]->realVars[349] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1355:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[288] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[14] /* Unmixed.pipe2.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe2.plugFlowPipe.timDel.u) */, tmp21, tmp22, tmp23 ,&data->localData[0]->realVars[287] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1458:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[226] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[9] /* Unmixed.pipe1.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe1.plugFlowPipe.timDel.u) */, tmp24, tmp25, tmp26 ,&data->localData[0]->realVars[225] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1681:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[223] /* Unmixed.pipe1.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[385] /* Unmixed.port_a1.h_outflow variable */, data->localData[0]->realVars[261] /* Unmixed.pipe1.port_b.h_outflow variable */, data->localData[0]->realVars[8] /* Unmixed.pipe1.plugFlowPipe.del.x STATE(1,Unmixed.pipe1.plugFlowPipe.v) */, tmp27, tmp28, tmp29 ,&data->localData[0]->realVars[208] /* Unmixed.pipe1.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1834:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[347] /* Unmixed.pipe3.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[386] /* Unmixed.port_a2.h_outflow variable */, data->localData[0]->realVars[390] /* Unmixed.port_b2.h_outflow variable */, (0.5) * (data->localData[0]->realVars[18] /* Unmixed.pipe3.plugFlowPipe.del.x STATE(1,Unmixed.pipe3.plugFlowPipe.v) */), tmp34, tmp35, tmp36 ,&data->localData[0]->realVars[332] /* Unmixed.pipe3.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1987:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[285] /* Unmixed.pipe2.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[323] /* Unmixed.pipe2.port_a.h_outflow variable */, data->localData[0]->realVars[388] /* Unmixed.port_b1.h_outflow variable */, data->localData[0]->realVars[13] /* Unmixed.pipe2.plugFlowPipe.del.x STATE(1,Unmixed.pipe2.plugFlowPipe.v) */, tmp41, tmp42, tmp43 ,&data->localData[0]->realVars[270] /* Unmixed.pipe2.plugFlowPipe.del.port_b.h_outflow variable */); ^ 8 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.h:3: In file included from ./meta/meta_modelica.h:49: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:4425:10: warning: equality comparison with extraneous parentheses [-Wparentheses-equality] if((_n == ((modelica_integer) 1))) ~~~^~~~~~~~~~~~~~~~~~~~~~~~~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:4425:10: note: remove extraneous parentheses around the comparison to silence this warning if((_n == ((modelica_integer) 1))) ~ ^ ~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:4425:10: note: use '=' to turn this equality comparison into an assignment if((_n == ((modelica_integer) 1))) ^~ = AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:5764:10: warning: equality comparison with extraneous parentheses [-Wparentheses-equality] if((_n == ((modelica_integer) 1))) ~~~^~~~~~~~~~~~~~~~~~~~~~~~~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:5764:10: note: remove extraneous parentheses around the comparison to silence this warning if((_n == ((modelica_integer) 1))) ~ ^ ~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:5764:10: note: use '=' to turn this equality comparison into an assignment if((_n == ((modelica_integer) 1))) ^~ = AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:6087:10: warning: equality comparison with extraneous parentheses [-Wparentheses-equality] if((_n == ((modelica_integer) 1))) ~~~^~~~~~~~~~~~~~~~~~~~~~~~~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:6087:10: note: remove extraneous parentheses around the comparison to silence this warning if((_n == ((modelica_integer) 1))) ~ ^ ~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:6087:10: note: use '=' to turn this equality comparison into an assignment if((_n == ((modelica_integer) 1))) ^~ = AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:6093:12: warning: equality comparison with extraneous parentheses [-Wparentheses-equality] if((_n == ((modelica_integer) 2))) ~~~^~~~~~~~~~~~~~~~~~~~~~~~~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:6093:12: note: remove extraneous parentheses around the comparison to silence this warning if((_n == ((modelica_integer) 2))) ~ ^ ~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:6093:12: note: use '=' to turn this equality comparison into an assignment if((_n == ((modelica_integer) 2))) ^~ = 6 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_records.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_records.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_records.c:4: In file included from ./meta/meta_modelica.h:49: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_01exo.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_01exo.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_01exo.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_02nls.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_02nls.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_02nls.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_03lsy.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_03lsy.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_03lsy.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_04set.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_04set.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_04set.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_05evt.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_05evt.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_05evt.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1558:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[223] /* Unmixed.pipe1.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[385] /* Unmixed.port_a1.h_outflow variable */, data->localData[0]->realVars[261] /* Unmixed.pipe1.port_b.h_outflow variable */, data->localData[0]->realVars[8] /* Unmixed.pipe1.plugFlowPipe.del.x STATE(1,Unmixed.pipe1.plugFlowPipe.v) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[208] /* Unmixed.pipe1.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1608:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[226] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[9] /* Unmixed.pipe1.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe1.plugFlowPipe.timDel.u) */, tmp3, tmp4, tmp5 ,&data->localData[0]->realVars[225] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1728:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[288] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[14] /* Unmixed.pipe2.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe2.plugFlowPipe.timDel.u) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[287] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1818:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[347] /* Unmixed.pipe3.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[386] /* Unmixed.port_a2.h_outflow variable */, data->localData[0]->realVars[390] /* Unmixed.port_b2.h_outflow variable */, (0.5) * (data->localData[0]->realVars[18] /* Unmixed.pipe3.plugFlowPipe.del.x STATE(1,Unmixed.pipe3.plugFlowPipe.v) */), tmp3, tmp4, tmp5 ,&data->localData[0]->realVars[332] /* Unmixed.pipe3.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1868:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[350] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[19] /* Unmixed.pipe3.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe3.plugFlowPipe.timDel.u) */, tmp6, tmp7, tmp8 ,&data->localData[0]->realVars[349] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:2056:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[285] /* Unmixed.pipe2.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[323] /* Unmixed.pipe2.port_a.h_outflow variable */, data->localData[0]->realVars[388] /* Unmixed.port_b1.h_outflow variable */, data->localData[0]->realVars[13] /* Unmixed.pipe2.plugFlowPipe.del.x STATE(1,Unmixed.pipe2.plugFlowPipe.v) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[270] /* Unmixed.pipe2.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:4689:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[223] /* Unmixed.pipe1.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[385] /* Unmixed.port_a1.h_outflow variable */, data->localData[0]->realVars[261] /* Unmixed.pipe1.port_b.h_outflow variable */, data->localData[0]->realVars[8] /* Unmixed.pipe1.plugFlowPipe.del.x STATE(1,Unmixed.pipe1.plugFlowPipe.v) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[208] /* Unmixed.pipe1.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:4717:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[226] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[9] /* Unmixed.pipe1.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe1.plugFlowPipe.timDel.u) */, tmp3, tmp4, tmp5 ,&data->localData[0]->realVars[225] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:4804:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[288] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[14] /* Unmixed.pipe2.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe2.plugFlowPipe.timDel.u) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[287] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:4850:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[347] /* Unmixed.pipe3.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[386] /* Unmixed.port_a2.h_outflow variable */, data->localData[0]->realVars[390] /* Unmixed.port_b2.h_outflow variable */, (0.5) * (data->localData[0]->realVars[18] /* Unmixed.pipe3.plugFlowPipe.del.x STATE(1,Unmixed.pipe3.plugFlowPipe.v) */), tmp3, tmp4, tmp5 ,&data->localData[0]->realVars[332] /* Unmixed.pipe3.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:4878:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[350] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[19] /* Unmixed.pipe3.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe3.plugFlowPipe.timDel.u) */, tmp6, tmp7, tmp8 ,&data->localData[0]->realVars[349] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:4989:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[285] /* Unmixed.pipe2.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[323] /* Unmixed.pipe2.port_a.h_outflow variable */, data->localData[0]->realVars[388] /* Unmixed.port_b1.h_outflow variable */, data->localData[0]->realVars[13] /* Unmixed.pipe2.plugFlowPipe.del.x STATE(1,Unmixed.pipe2.plugFlowPipe.v) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[270] /* Unmixed.pipe2.plugFlowPipe.del.port_b.h_outflow variable */); ^ 14 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_07dly.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_07dly.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_07dly.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_08bnd.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_08bnd.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_08bnd.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_09alg.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_09alg.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_09alg.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_10asr.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_10asr.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_10asr.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_11mix.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_11mix.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_11mix.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_12jac.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_12jac.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_12jac.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_13opt.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_13opt.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_13opt.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_14lnz.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_14lnz.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_14lnz.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_15syn.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_15syn.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_15syn.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_16dae.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_16dae.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_16dae.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_17inl.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_17inl.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_17inl.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_init_fmu.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_init_fmu.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_init_fmu.c:1: In file included from ./simulation_data.h:39: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.c:9: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.c:55: ./fmi-export/fmu2_model_interface.c.inc:79:11: warning: enumeration value 'modelSlaveInitialized' not handled in switch [-Wswitch] switch (comp->state) ^ ./fmi-export/fmu2_model_interface.c.inc:168:16: warning: passing 'char **' to parameter of type 'const char **' discards qualifiers in nested pointer types [-Wincompatible-pointer-types-discards-qualifiers] GC_vasprintf(&str, msg, args); ^~~~ ./gc/../meta/../util/modelica_string.h:71:31: note: passing argument to parameter 'strp' here int GC_vasprintf(const char **strp, const char *fmt, va_list ap); ^ 4 warnings generated. mkdir -p ../binaries/linux64 clang -shared -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump.so AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_records.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_01exo.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_02nls.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_03lsy.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_04set.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_05evt.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_07dly.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_08bnd.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_09alg.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_10asr.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_11mix.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_12jac.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_13opt.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_14lnz.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_15syn.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_16dae.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_17inl.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_init_fmu.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.o -L"/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Systems/HydraulicModules/Example" -Wl,-Bstatic "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc" "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/" "-L/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library/x86_64-linux" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library/x86_64-linux" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library/linux64" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library/linux64" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library" -lModelicaExternalC -Wl,-Bdynamic -L'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc' -Wl,-rpath,'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc' -lSimulationRuntimeFMI -Wl,--no-as-needed -Wl,--disable-new-dtags -llapack -lblas -lm -lpthread -rdynamic -Wl,--no-undefined /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_872': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x2645): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_881': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x2cad): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_889': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x32d0): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_907': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x3e2d): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_918': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x4536): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o:AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x4c34): more undefined references to `spatialDistribution' follow clang: error: linker command failed with exit code 1 (use -v to see invocation) make: *** [Makefile:58: nozip] Error 1