Running command: translateModel(Modelica_StateGraph2.Examples.BasicStateGraphs.ParallelOutsideDelay,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Modelica_StateGraph2_Modelica_StateGraph2.Examples.BasicStateGraphs.ParallelOutsideDelay") Notification: Performance of loadModel(Modelica_StateGraph2): time 1.916/1.916, allocations: 208.4 MB / 220.6 MB, free: 15.43 MB / 186.7 MB Notification: Performance of FrontEnd - loaded program: time 3.706e-05/3.719e-05, allocations: 8 kB / 271.2 MB, free: 12.69 MB / 234.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2585/0.2586, allocations: 47.78 MB / 319 MB, free: 12.25 MB / 266.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.1112/0.3698, allocations: 72.84 MB / 391.9 MB, free: 4.926 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0001399/0.37, allocations: 47.98 kB / 391.9 MB, free: 4.879 MB / 330.7 MB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica_StateGraph2 2.0.3/package.mo:12150:5-12156:3:writable] Warning: Usage of non-standard operator (not specified in the Modelica specification): Connections.uniqueRoot. Functionality might be partially supported but is not guaranteed. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica_StateGraph2 2.0.3/package.mo:12834:3-12834:32:writable] Warning: Connecting two signal sources while connecting inPort[1].checkOneDelayedTransitionPerLoop to local_inPort[1].checkOneDelayedTransitionPerLoop. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica_StateGraph2 2.0.3/package.mo:12834:3-12834:32:writable] Warning: Connecting two signal sources while connecting inPort[1].fire to local_inPort[1].fire. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica_StateGraph2 2.0.3/package.mo:12835:3-12835:34:writable] Warning: Connecting two signal sources while connecting outPort[1].fire to local_outPort[1].fire. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica_StateGraph2 2.0.3/package.mo:12838:3-12838:30:writable] Warning: Connecting two signal sources while connecting entry[1].checkUnaryConnection to local_entry[1].checkUnaryConnection. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica_StateGraph2 2.0.3/package.mo:12838:3-12838:30:writable] Warning: Connecting two signal sources while connecting entry[2].checkUnaryConnection to local_entry[2].checkUnaryConnection. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica_StateGraph2 2.0.3/package.mo:12840:5-12840:30:writable] Warning: Connecting two signal sources while connecting exit[1].available to local_exit[1].available. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica_StateGraph2 2.0.3/package.mo:12840:5-12840:30:writable] Warning: Connecting two signal sources while connecting exit[1].checkOneDelayedTransitionPerLoop to local_exit[1].checkOneDelayedTransitionPerLoop. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica_StateGraph2 2.0.3/package.mo:12840:5-12840:30:writable] Warning: Connecting two signal sources while connecting exit[2].available to local_exit[2].available. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica_StateGraph2 2.0.3/package.mo:12840:5-12840:30:writable] Warning: Connecting two signal sources while connecting exit[2].checkOneDelayedTransitionPerLoop to local_exit[2].checkOneDelayedTransitionPerLoop. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica_StateGraph2 2.0.3/package.mo:14984:7-14990:3:writable] Warning: Usage of non-standard operator (not specified in the Modelica specification): Connections.uniqueRoot. Functionality might be partially supported but is not guaranteed. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica_StateGraph2 2.0.3/package.mo:14992:7-14999:4:writable] Warning: Usage of non-standard operator (not specified in the Modelica specification): Connections.uniqueRootIndices. Functionality might be partially supported but is not guaranteed. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica_StateGraph2 2.0.3/package.mo:14992:7-14999:4:writable] Error: Wrong type or wrong number of arguments to Connections.uniqueRootIndices(local_entry.node, local_exit.node, " The connection structure in a Parallel component is not correct: There must be exactly one unique path from every exit port to every entry port. This is not the case here. "). (in component parallel). Error: Error occurred while flattening model Modelica_StateGraph2.Examples.BasicStateGraphs.ParallelOutsideDelay Notification: Performance of FrontEnd: time 0.01573/0.3857, allocations: 4.114 MB / 396 MB, free: 0.75 MB / 330.7 MB