Regular simulation: ./Buildings_6.0.0_Buildings.Fluid.HeatExchangers.DXCoils.BaseClasses.Examples.EvaporationPulse -abortSlowSimulation -alarm=480 assert | warning | The following assertion has been violated at time 0.000000 | | | | false assert | warning | Nominal variable violating min constraint: 0.0 <= evaSho.m, has value: -3.10146 assert | warning | The following assertion has been violated at time 0.000000 | | | | false assert | warning | Nominal variable violating min constraint: 0.0 <= evaNor.m, has value: -3.10146 assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | evaSho.nomVal.gamma <= evaSho.gammaMax assert | warning | *** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 1.00359, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 0.497018 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00614376 - 0.00715296 = -0.0010092 | | | | QLat_flow_nominal = -1000 assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | evaSho.dX_nominal > 1e-10 assert | warning | *** Warning: In DX coil model, dX_nominal = -0.0010092 | | | | This means that the coil is not dehumidifying air at the nominal conditions. | | | | Check nominal parameters. | | | | Nominal values: | | | | Q_flow_nominal = -5000 | | | | COP_nominal = 3 | | | | m_flow_nominal = 0.497018 | | | | TEvaIn_nominal = 292.55 (= 19.4 degC) | | | | TConIn_nominal = 308.15 (= 35 degC) | | | | phiIn_nominal = 0.5 | | | | tWet = 1400 | | | | gamma = 1.5 | | | | p_nominal = 101325 assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | evaNor.nomVal.gamma <= evaNor.gammaMax assert | warning | *** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 1.00359, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 0.497018 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00614376 - 0.00715296 = -0.0010092 | | | | QLat_flow_nominal = -1000 assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | evaNor.dX_nominal > 1e-10 assert | warning | *** Warning: In DX coil model, dX_nominal = -0.0010092 | | | | This means that the coil is not dehumidifying air at the nominal conditions. | | | | Check nominal parameters. | | | | Nominal values: | | | | Q_flow_nominal = -5000 | | | | COP_nominal = 3 | | | | m_flow_nominal = 0.497018 | | | | TEvaIn_nominal = 292.55 (= 19.4 degC) | | | | TConIn_nominal = 308.15 (= 35 degC) | | | | phiIn_nominal = 0.5 | | | | tWet = 1400 | | | | gamma = 1.5 | | | | p_nominal = 101325 LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | warning | The following assertion has been violated at time 900.000000 | | | | evaSho.dX >= 0.0 and evaSho.dX <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= evaSho.dX <= 1.0, has value: -0.00248009 assert | warning | The following assertion has been violated at time 1800.000000 | | | | evaNor.dX >= 0.0 and evaNor.dX <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= evaNor.dX <= 1.0, has value: -0.00248009 LOG_SUCCESS | info | The simulation finished successfully.