Running command: translateModel(Buildings.Experimental.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Experimental.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall") Notification: Performance of loadModel(Buildings): time 3.9/3.9, allocations: 432.8 MB / 444.9 MB, free: 15.67 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 2.913e-05/2.924e-05, allocations: 3.406 kB / 0.5337 GB, free: 12.29 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1742/0.1743, allocations: 98.72 MB / 0.6301 GB, free: 6.215 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.578/6.753, allocations: 2.588 GB / 3.218 GB, free: 43.41 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002185/6.753, allocations: 91.66 kB / 3.218 GB, free: 43.37 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2346:7-2347:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$larOff$loa.getDerTableValue. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2312:7-2313:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$larOff$loa.getTableValue. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$larOff$loa.getTableTimeTmin. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$larOff$loa.getTableTimeTmax. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Experimental/DistrictHeatingCooling/SubStations/VaporCompression/HeatingCoolingHotwaterTimeSeries_dT.mo:235:3-247:75:writable] Error: Variable larOff.chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$larOff$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Experimental.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall Notification: Performance of FrontEnd: time 1.092/7.845, allocations: 216.2 MB / 3.429 GB, free: 161.3 MB / 0.823 GB