Running command: translateModel(Buildings.Experimental.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_5.0.1_Buildings.Experimental.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT") Notification: Performance of loadModel(Buildings): time 3.547/3.547, allocations: 403.3 MB / 415.4 MB, free: 13.02 MB / 330.7 MB Notification: Performance of FrontEnd - loaded program: time 3.322e-05/3.352e-05, allocations: 7.984 kB / 0.499 GB, free: 13.45 MB / 426.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4787/0.4787, allocations: 92.7 MB / 0.5896 GB, free: 14.51 MB / 490.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 6.044/6.523, allocations: 2.501 GB / 3.09 GB, free: 64.87 MB / 0.7761 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002591/6.523, allocations: 99.89 kB / 3.09 GB, free: 64.81 MB / 0.7761 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2346:7-2347:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$subSta$loa.getDerTableValue. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2312:7-2313:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$subSta$loa.getTableValue. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$subSta$loa.getTableTimeTmin. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$subSta$loa.getTableTimeTmax. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/Experimental/DistrictHeatingCooling/SubStations/VaporCompression/HeatingCoolingHotwaterTimeSeries_dT.mo:235:3-247:75:writable] Error: Variable subSta.chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$subSta$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Experimental.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT Notification: Performance of FrontEnd: time 1.01/7.533, allocations: 212.5 MB / 3.298 GB, free: 166.7 MB / 0.7761 GB