Running command: translateModel(BuildingSystems.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow") Notification: Performance of loadModel(BuildingSystems): time 3.013/3.013, allocations: 343.8 MB / 355.9 MB, free: 9.379 MB / 298.7 MB Notification: Performance of FrontEnd - loaded program: time 3.477e-05/3.493e-05, allocations: 4 kB / 436.6 MB, free: 2.477 MB / 346.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1398/0.1399, allocations: 77.73 MB / 0.5022 GB, free: 4.586 MB / 426.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 1.282/1.421, allocations: 387.7 MB / 0.8808 GB, free: 141.7 MB / 0.6511 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002528/1.422, allocations: 86.88 kB / 0.8809 GB, free: 141.7 MB / 0.6511 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/BuildingSystems 2.0.0-beta/Fluid/Chillers/Validation/Carnot_TEva_reverseFlow.mo:22:3-37:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope BuildingSystems.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model BuildingSystems.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow Notification: Performance of FrontEnd: time 0.2193/1.641, allocations: 81.21 MB / 0.9602 GB, free: 63.09 MB / 0.6511 GB