OMSimulator --tempDir=temp_Modelica_3_1_cpp_Modelica_Fluid_Examples_AST_BatchPlant_BatchPlant_StandardWater_fmu --startTime=0 --stopTime=3600 --timeout=50 --tolerance=1e-06 Modelica_3_1_cpp_Modelica_Fluid_Examples_AST_BatchPlant_BatchPlant_StandardWater.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_Modelica_3_1_cpp_Modelica_Fluid_Examples_AST_BatchPlant_BatchPlant_StandardWater_fmu" info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.1_cpp_Modelica.Fluid.Examples.AST_BatchPlant.BatchPlant_StandardWater/temp_Modelica_3_1_cpp_Modelica_Fluid_Examples_AST_BatchPlant_BatchPlant_StandardWater_fmu" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.1_cpp_Modelica.Fluid.Examples.AST_BatchPlant.BatchPlant_StandardWater" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Modelica_3.1_cpp_Modelica.Fluid.Examples.AST_BatchPlant.BatchPlant_StandardWater/temp_Modelica_3_1_cpp_Modelica_Fluid_Examples_AST_BatchPlant_BatchPlant_StandardWater_fmu/model-7tubqxvj" warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipePump2B2.flowModel.dp_small <= 1000000000.0, has value: 1.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipePump2B2.flowModel.dp_nominal <= 1000000000.0, has value: 1000.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipePump1B1.flowModel.dp_small <= 1000000000.0, has value: 1.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipePump1B1.flowModel.dp_nominal <= 1000000000.0, has value: 1000.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipeB7Pump.flowModel.dp_small <= 1000000000.0, has value: 1.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipeB7Pump.flowModel.dp_nominal <= 1000000000.0, has value: 1000.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipeB6Pump.flowModel.dp_small <= 1000000000.0, has value: 1.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipeB6Pump.flowModel.dp_nominal <= 1000000000.0, has value: 1000.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipeB1B1.flowModel.dp_small <= 1000000000.0, has value: 1.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipeB1B1.flowModel.dp_nominal <= 1000000000.0, has value: 1000.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipeB2B3.flowModel.dp_small <= 1000000000.0, has value: 1.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipeB2B3.flowModel.dp_nominal <= 1000000000.0, has value: 1000.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipeB1B3.flowModel.dp_small <= 1000000000.0, has value: 1.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipeB1B3.flowModel.dp_nominal <= 1000000000.0, has value: 1000.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipeB1B2.flowModel.dp_small <= 1000000000.0, has value: 1.000000 warning: fmu (logStatusWarning): Variable violating min/max constraint: 2000.0 <= pipeB1B2.flowModel.dp_nominal <= 1000000000.0, has value: 1000.000000 error: [fmi2logger] fmu (logStatusError): IF97 medium function tsat called with too low pressure p = nan Pa <= 611.657000 Pa (triple point pressure) error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.fmu" error: [initialize] Initialization of system "model.root" failed error: [simulate] Model "model" is in wrong model state info: 16 warnings info: 4 errors