Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_Chillers_Validation_Carnot_TEva_HighTemperature",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(Buildings): time 4.221/4.221, allocations: 460.4 MB / 472.6 MB, free: 5.398 MB / 378.7 MB Notification: Performance of FrontEnd - loaded program: time 3.706e-05/3.718e-05, allocations: 4 kB / 0.5682 GB, free: 10.09 MB / 458.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2313/0.2314, allocations: 106.2 MB / 0.6719 GB, free: 15.69 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.265/1.497, allocations: 414.6 MB / 1.077 GB, free: 13.22 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003119/1.497, allocations: 97.05 kB / 1.077 GB, free: 13.17 MB / 0.8698 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 7.0.0/Fluid/Chillers/Examples/Carnot_TEva.mo:19:3-33:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature Notification: Performance of FrontEnd: time 0.8334/2.33, allocations: 82.4 MB / 1.157 GB, free: 287.3 MB / 0.8698 GB