Running command: "" <> buildModelFMU(Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_Boilers_Examples_BoilerPolynomialClosedLoop",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(Buildings): time 4.667/4.667, allocations: 460.4 MB / 472.6 MB, free: 5.387 MB / 378.7 MB Notification: Performance of FrontEnd - loaded program: time 3.822e-05/3.845e-05, allocations: 4 kB / 0.5682 GB, free: 10.07 MB / 458.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2358/0.2359, allocations: 106.2 MB / 0.6719 GB, free: 15.67 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 2.032/2.268, allocations: 451.3 MB / 1.113 GB, free: 244.8 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003599/2.268, allocations: 94.53 kB / 1.113 GB, free: 244.8 MB / 0.8698 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 7.0.0/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 7.0.0/Fluid/Boilers/Examples/BoilerPolynomialClosedLoop.mo:11:3-21:72:writable] Error: component boi contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop Notification: Performance of FrontEnd: time 0.7111/2.979, allocations: 224.6 MB / 1.332 GB, free: 85.52 MB / 0.8698 GB