Running command: "" <> buildModelFMU(Buildings.Air.Systems.SingleZone.VAV.Examples.ChillerDXHeatingEconomizer,fileNamePrefix="Buildings_6_0_0_Buildings_Air_Systems_SingleZone_VAV_Examples_ChillerDXHeatingEconomizer",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(Buildings): time 4.092/4.092, allocations: 432.7 MB / 444.9 MB, free: 15.7 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 3.72e-05/3.717e-05, allocations: 3.406 kB / 0.5338 GB, free: 12.23 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2194/0.2194, allocations: 98.73 MB / 0.6302 GB, free: 6.133 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 8.756/8.976, allocations: 2.686 GB / 3.316 GB, free: 180.2 MB / 0.8386 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004021/8.976, allocations: 100.6 kB / 3.316 GB, free: 180.2 MB / 0.8386 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2331:7-2332:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooHea.getTableValueNoDer. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooHea.getTableTimeTmin. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooHea.getTableTimeTmax. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2331:7-2332:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooCoo.getTableValueNoDer. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooCoo.getTableTimeTmin. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooCoo.getTableTimeTmax. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/Outside.mo:28:3-31:49:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/PartialSource.mo:38:3-40:49:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg", final quantity = Medium.substanceNames) "Needed to connect to conditional connector" second element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg") "Needed to connect to conditional connector" Error: Error occurred while flattening model Buildings.Air.Systems.SingleZone.VAV.Examples.ChillerDXHeatingEconomizer Notification: Performance of FrontEnd: time 0.5111/9.488, allocations: 150.6 MB / 3.463 GB, free: 151.4 MB / 0.8386 GB