OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Fluid_Sensors_Examples_TraceSubstances_fmu --startTime=0 --stopTime=7200 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Fluid_Sensors_Examples_TraceSubstances.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_BuildingSystems_BuildingSystems_Fluid_Sensors_Examples_TraceSubstances_fmu" info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.Sensors.Examples.TraceSubstances/temp_BuildingSystems_BuildingSystems_Fluid_Sensors_Examples_TraceSubstances_fmu" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.Sensors.Examples.TraceSubstances" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.Sensors.Examples.TraceSubstances/temp_BuildingSystems_BuildingSystems_Fluid_Sensors_Examples_TraceSubstances_fmu/model-dsprj5zq" warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/BuildingSystems 2.0.0-beta/Fluid/Interfaces/PartialTwoPortInterface.mo:19: The following assertion has been violated at time 0.000000 (if res.m_flow_nominal_pos > 1e-15 then res.m_flow_nominal_pos else 1.0) >= -100000.0 and (if res.m_flow_nominal_pos > 1e-15 then res.m_flow_nominal_pos else 1.0) <= 0.0 assert | warning | Nominal variable violating min/max constraint: -100000.0 <= res.m_flow <= 0.0, has value: 0.005 warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/BuildingSystems 2.0.0-beta/Fluid/Interfaces/PartialTwoPortInterface.mo:19: The following assertion has been violated at time 0.000000 res.m_flow >= -100000.0 and res.m_flow <= 0.0 assert | warning | Variable violating min/max constraint: -100000.0 <= res.m_flow <= 0.0, has value: 2.18279e-14 info: maximum step size for 'model.root': 0.100000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.fmu.senPPM.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.fmu.senSou.substanceName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.fmu.senTraSub.substanceName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.fmu.senTraSubNoFlorRev.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.fmu.senVol.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.fmu.sou.substanceName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 72003 NumRhsEvals = 72005 NumLinSolvSetups = 3603 NumNonlinSolvIters = 72004 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors