OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Buildings_Constructions_Examples_WindowWithAirpathsFlexGeo_fmu --startTime=0 --stopTime=7200 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Buildings_Constructions_Examples_WindowWithAirpathsFlexGeo.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_BuildingSystems_BuildingSystems_Buildings_Constructions_Examples_WindowWithAirpathsFlexGeo_fmu" info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Constructions.Examples.WindowWithAirpathsFlexGeo/temp_BuildingSystems_BuildingSystems_Buildings_Constructions_Examples_WindowWithAirpathsFlexGeo_fmu" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Constructions.Examples.WindowWithAirpathsFlexGeo" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Constructions.Examples.WindowWithAirpathsFlexGeo/temp_BuildingSystems_BuildingSystems_Buildings_Constructions_Examples_WindowWithAirpathsFlexGeo_fmu/model-fs49s9un" stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Buildings.Constructions.Examples.WindowWithAirpathsFlexGeo/temp_BuildingSystems_BuildingSystems_Buildings_Constructions_Examples_WindowWithAirpathsFlexGeo_fmu/model-fs49s9un/temp/fmu/resources/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/BuildingSystems 2.0.0-beta/Climate/weather/USA_SanFrancisco.txt" warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/BuildingSystems 2.0.0-beta/Climate/WeatherData/BaseClasses/WeatherDataFileGeneral.mo:21: The following assertion has been violated at time 0.000000 ambience.weatherDataReader.weatherData.phiAir >= 0.0 and ambience.weatherDataReader.weatherData.phiAir <= 1.01 assert | warning | Variable violating min/max constraint: 0.0 <= ambience.weatherDataReader.weatherData.phiAir <= 1.01, has value: 1.0225 info: maximum step size for 'model.root': 0.100000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.fmu.ambience.weatherDataReader.weatherData.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.fmu.ambience.weatherDataReader.weatherData.datRea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.fmu.ambience.weatherDataReader.weatherData.filNam will not be stored in the result file, because the signal type is not supported info: Parameter model.root.fmu.ambience.weatherDataReader.weatherData.info will not be stored in the result file, because the signal type is not supported info: Parameter model.root.fmu.ambience.weatherDataReader.weatherData.tabNam will not be stored in the result file, because the signal type is not supported info: Parameter model.root.fmu.window.heatTransfer.material.name will not be stored in the result file, because the signal type is not supported [CVODE ERROR] CVode At t = 126.099, mxstep steps taken before reaching tout. error: [stepUntil] SUNDIALS_ERROR: CVode() failed with flag = -1