Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr SiemensPower_SiemensPower.Components.Pipes.Tests.tube_ownMedia_test.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo", uses=false) Using package SiemensPower with version 2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo) Using package ModelicaServices with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo) Using package Modelica with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo) Using package Complex with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo) Running command: translateModel(SiemensPower.Components.Pipes.Tests.tube_ownMedia_test,tolerance=1e-05,outputFormat="empty",numberOfIntervals=4000,variableFilter="",fileNamePrefix="SiemensPower_SiemensPower.Components.Pipes.Tests.tube_ownMedia_test") translateModel(SiemensPower.Components.Pipes.Tests.tube_ownMedia_test,tolerance=1e-05,outputFormat="empty",numberOfIntervals=4000,variableFilter="",fileNamePrefix="SiemensPower_SiemensPower.Components.Pipes.Tests.tube_ownMedia_test") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo): time 0.001473/0.001473, allocations: 169.9 kB / 12.72 MB, free: 2.594 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo): time 1.244/1.244, allocations: 170.6 MB / 183.8 MB, free: 11.42 MB / 154.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo): time 0.001634/0.001635, allocations: 99.52 kB / 223.2 MB, free: 4.039 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo): time 0.02711/0.02711, allocations: 5.614 MB / 268 MB, free: 21.78 MB / 202.7 MB Notification: Performance of FrontEnd - loaded program: time 6.66e-05/6.664e-05, allocations: 4 kB / 316 MB, free: 5.781 MB / 234.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2532/0.2533, allocations: 40.03 MB / 356 MB, free: 35.23 MB / 250.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 6.756/7.009, allocations: 2.665 GB / 3.013 GB, free: 67.3 MB / 378.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0001401/7.01, allocations: 51.45 kB / 3.013 GB, free: 67.28 MB / 378.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/Components/Pipes/Tests/tube_ownMedia_test.mo:9:3-13:81:writable] Error: Variable watersink_ph: In modifier (use_p_in = true), class or component use_p_in not found in . Error: Error occurred while flattening model SiemensPower.Components.Pipes.Tests.tube_ownMedia_test Notification: Performance of FrontEnd: time 0.6094/7.619, allocations: 139.6 MB / 3.149 GB, free: 75.75 MB / 378.7 MB