Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_latest_PowerSystems.Examples.AC3ph.Generation.Islanding.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo", uses=false) Using package PowerSystems with version 1.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerSystems.Examples.AC3ph.Generation.Islanding,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="ACpower.p.1.|ACpower.p.2.|ACpower.p.3.|DCpower.p|DCvoltage.v|Time",fileNamePrefix="PowerSystems_latest_PowerSystems.Examples.AC3ph.Generation.Islanding") translateModel(PowerSystems.Examples.AC3ph.Generation.Islanding,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="ACpower.p.1.|ACpower.p.2.|ACpower.p.3.|DCpower.p|DCvoltage.v|Time",fileNamePrefix="PowerSystems_latest_PowerSystems.Examples.AC3ph.Generation.Islanding") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00117/0.00117, allocations: 177.1 kB / 13.64 MB, free: 1.672 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.356/1.356, allocations: 205.2 MB / 219.4 MB, free: 14.26 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007883/0.0007883, allocations: 78.67 kB / 267.5 MB, free: 14.1 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo): time 0.1619/0.1619, allocations: 37.98 MB / 353.5 MB, free: 1.75 MB / 250.7 MB Notification: Performance of FrontEnd - loaded program: time 2.949e-05/2.953e-05, allocations: 4 kB / 417.7 MB, free: 29.12 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1111/0.1111, allocations: 56.32 MB / 474.1 MB, free: 4.801 MB / 314.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.4296/0.5407, allocations: 137.4 MB / 0.5972 GB, free: 13.99 MB / 410.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002204/0.541, allocations: 94.06 kB / 0.5973 GB, free: 13.95 MB / 410.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/AC3ph/Machines.mo:2240:3-2240:48:writable] Error: Could not evaluate structural parameter (or constant): n_d which gives dimensions of array: L_rd[n_d]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.AC3ph.Generation.Islanding Notification: Performance of FrontEnd: time 0.1148/0.6558, allocations: 42.63 MB / 0.6389 GB, free: 8.809 MB / 442.7 MB