Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_cpp_PowerSystems.Examples.AC3ph.Generation.WindGeneratorLine.conf.json loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo", uses=false) Using package PowerSystems with version 1.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo) Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerSystems.Examples.AC3ph.Generation.WindGeneratorLine,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2000,variableFilter="",fileNamePrefix="PowerSystems_cpp_PowerSystems.Examples.AC3ph.Generation.WindGeneratorLine") translateModel(PowerSystems.Examples.AC3ph.Generation.WindGeneratorLine,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2000,variableFilter="",fileNamePrefix="PowerSystems_cpp_PowerSystems.Examples.AC3ph.Generation.WindGeneratorLine") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.009267/0.009267, allocations: 185.3 kB / 13.19 MB, free: 2.125 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.167/2.167, allocations: 205.2 MB / 218.9 MB, free: 9.195 MB / 186.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00114/0.001141, allocations: 98.39 kB / 267.1 MB, free: 9.27 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo): time 0.2713/0.2713, allocations: 37.97 MB / 353.1 MB, free: 3.047 MB / 298.7 MB Notification: Performance of FrontEnd - loaded program: time 4.276e-05/4.296e-05, allocations: 4 kB / 416.8 MB, free: 41.27 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1421/0.1422, allocations: 56.32 MB / 473.1 MB, free: 0.8984 MB / 314.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.513/0.6552, allocations: 122.3 MB / 0.5815 GB, free: 13.35 MB / 426.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.002396/0.6577, allocations: 0.6838 MB / 0.5822 GB, free: 12.67 MB / 426.7 MB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/AC3ph/Machines.mo:2208:3-2208:47:writable] Error: Could not evaluate structural parameter (or constant): n_r which gives dimensions of array: L_r[n_r]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.AC3ph.Generation.WindGeneratorLine Notification: Performance of FrontEnd: time 0.1582/0.8159, allocations: 32.35 MB / 0.6137 GB, free: 11.98 MB / 458.7 MB