Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_cpp_PowerSystems.Examples.AC3ph.Generation.Islanding.conf.json loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo", uses=false) Using package PowerSystems with version 1.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo) Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerSystems.Examples.AC3ph.Generation.Islanding,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_cpp_PowerSystems.Examples.AC3ph.Generation.Islanding") translateModel(PowerSystems.Examples.AC3ph.Generation.Islanding,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_cpp_PowerSystems.Examples.AC3ph.Generation.Islanding") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001508/0.001508, allocations: 185.4 kB / 13.19 MB, free: 2.125 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.134/2.134, allocations: 205.2 MB / 218.9 MB, free: 9.207 MB / 186.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001111/0.00111, allocations: 80.91 kB / 267.1 MB, free: 9.277 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo): time 0.3086/0.3086, allocations: 37.97 MB / 353.1 MB, free: 3.059 MB / 298.7 MB Notification: Performance of FrontEnd - loaded program: time 3.408e-05/3.422e-05, allocations: 4 kB / 416.8 MB, free: 41.3 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1078/0.1078, allocations: 56.31 MB / 473.1 MB, free: 0.9258 MB / 314.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.555/0.6629, allocations: 137.4 MB / 0.5963 GB, free: 14.21 MB / 442.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003142/0.6633, allocations: 99.94 kB / 0.5964 GB, free: 14.12 MB / 442.7 MB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/AC3ph/Machines.mo:2240:3-2240:48:writable] Error: Could not evaluate structural parameter (or constant): n_d which gives dimensions of array: L_rd[n_d]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.AC3ph.Generation.Islanding Notification: Performance of FrontEnd: time 0.208/0.8713, allocations: 42.62 MB / 0.638 GB, free: 3.016 MB / 474.7 MB