Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_PowerSystems.Examples.Wind.WindTurbine_DFIG.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo", uses=false) Using package PowerSystems with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Running command: translateModel(PowerSystems.Examples.Wind.WindTurbine_DFIG,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_PowerSystems.Examples.Wind.WindTurbine_DFIG") translateModel(PowerSystems.Examples.Wind.WindTurbine_DFIG,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_PowerSystems.Examples.Wind.WindTurbine_DFIG") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001186/0.001186, allocations: 182.7 kB / 13.64 MB, free: 1.676 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.752/1.752, allocations: 194.3 MB / 208.4 MB, free: 6.703 MB / 170.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.001674/0.001674, allocations: 114.3 kB / 253.5 MB, free: 9.582 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo): time 0.1614/0.1614, allocations: 37.9 MB / 336.4 MB, free: 14.26 MB / 250.7 MB Notification: Performance of FrontEnd - loaded program: time 3.977e-05/3.981e-05, allocations: 4 kB / 397.5 MB, free: 1.059 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2939/0.2939, allocations: 53.22 MB / 450.8 MB, free: 13.48 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.5461/0.8401, allocations: 132.8 MB / 0.5699 GB, free: 26.27 MB / 378.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002793/0.8405, allocations: 84.89 kB / 0.57 GB, free: 26.26 MB / 378.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/AC3ph/Machines.mo:2208:3-2208:47:writable] Error: Could not evaluate structural parameter (or constant): n_r which gives dimensions of array: L_r[n_r]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.Wind.WindTurbine_DFIG Notification: Performance of FrontEnd: time 0.06661/0.9071, allocations: 25.19 MB / 0.5946 GB, free: 14.76 MB / 378.7 MB