Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_PowerSystems.Examples.AC3ph.Generation.Islanding.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo", uses=false) Using package PowerSystems with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Running command: translateModel(PowerSystems.Examples.AC3ph.Generation.Islanding,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_PowerSystems.Examples.AC3ph.Generation.Islanding") translateModel(PowerSystems.Examples.AC3ph.Generation.Islanding,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_PowerSystems.Examples.AC3ph.Generation.Islanding") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001543/0.001543, allocations: 182.4 kB / 13.64 MB, free: 1.676 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.679/1.679, allocations: 194.3 MB / 208.4 MB, free: 6.703 MB / 170.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.001633/0.001633, allocations: 116.7 kB / 253.5 MB, free: 9.582 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo): time 0.1653/0.1653, allocations: 37.9 MB / 336.4 MB, free: 14.26 MB / 250.7 MB Notification: Performance of FrontEnd - loaded program: time 3.191e-05/3.234e-05, allocations: 0 / 397.5 MB, free: 1.043 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3058/0.3059, allocations: 53.23 MB / 450.8 MB, free: 13.48 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.4674/0.7733, allocations: 131.4 MB / 0.5685 GB, free: 26.79 MB / 378.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0001985/0.7736, allocations: 92.03 kB / 0.5686 GB, free: 26.78 MB / 378.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/AC3ph/Machines.mo:2240:3-2240:48:writable] Error: Could not evaluate structural parameter (or constant): n_d which gives dimensions of array: L_rd[n_d]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.AC3ph.Generation.Islanding Notification: Performance of FrontEnd: time 0.09808/0.8717, allocations: 42.62 MB / 0.6102 GB, free: 0.5312 MB / 378.7 MB