Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_PowerSystems.Examples.AC3ph.Elementary.Machines.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo", uses=false) Using package PowerSystems with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Running command: translateModel(PowerSystems.Examples.AC3ph.Elementary.Machines,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_PowerSystems.Examples.AC3ph.Elementary.Machines") translateModel(PowerSystems.Examples.AC3ph.Elementary.Machines,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_PowerSystems.Examples.AC3ph.Elementary.Machines") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001174/0.001174, allocations: 181.8 kB / 13.64 MB, free: 1.676 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.682/1.682, allocations: 194.3 MB / 208.4 MB, free: 6.707 MB / 170.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.001599/0.001599, allocations: 120.7 kB / 253.5 MB, free: 9.578 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo): time 0.1563/0.1563, allocations: 37.92 MB / 336.4 MB, free: 14.25 MB / 250.7 MB Notification: Performance of FrontEnd - loaded program: time 3.915e-05/3.917e-05, allocations: 4 kB / 397.5 MB, free: 1.039 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3282/0.3282, allocations: 53.21 MB / 450.7 MB, free: 13.49 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.4457/0.774, allocations: 108.9 MB / 0.5466 GB, free: 28.99 MB / 378.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003006/0.7744, allocations: 86.22 kB / 0.5467 GB, free: 28.99 MB / 378.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/AC3ph/Machines.mo:2208:3-2208:47:writable] Error: Could not evaluate structural parameter (or constant): n_r which gives dimensions of array: L_r[n_r]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.AC3ph.Elementary.Machines Notification: Performance of FrontEnd: time 0.07839/0.8528, allocations: 28.83 MB / 0.5748 GB, free: 22.23 MB / 378.7 MB