Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.TestTransformerWithTapChangerMax.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: translateModel(PowerGrids.Electrical.Test.TestTransformerWithTapChangerMax,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.TestTransformerWithTapChangerMax") translateModel(PowerGrids.Electrical.Test.TestTransformerWithTapChangerMax,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.TestTransformerWithTapChangerMax") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001017/0.001017, allocations: 174.9 kB / 12.73 MB, free: 2.59 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.268/1.268, allocations: 205.2 MB / 218.5 MB, free: 9.211 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007538/0.0007537, allocations: 81.92 kB / 266.6 MB, free: 9.27 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo): time 0.05851/0.05851, allocations: 14.01 MB / 328.7 MB, free: 11.06 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 2.593e-05/2.604e-05, allocations: 0 / 389.6 MB, free: 66.28 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.07662/0.07666, allocations: 51.11 MB / 440.7 MB, free: 15.19 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.3395/0.4162, allocations: 96.35 MB / 0.5245 GB, free: 14.58 MB / 346.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002863/0.4165, allocations: 74.34 kB / 0.5246 GB, free: 14.55 MB / 346.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBus$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.TestTransformerWithTapChangerMax Notification: Performance of FrontEnd: time 0.02456/0.4411, allocations: 5.748 MB / 0.5302 GB, free: 9.887 MB / 346.7 MB