Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.TestTransformerFixedRatio.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerGrids.Electrical.Test.TestTransformerFixedRatio,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.TestTransformerFixedRatio") translateModel(PowerGrids.Electrical.Test.TestTransformerFixedRatio,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.TestTransformerFixedRatio") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001012/0.001013, allocations: 174.7 kB / 12.73 MB, free: 2.59 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.376/1.376, allocations: 205.2 MB / 218.5 MB, free: 9.223 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008236/0.0008237, allocations: 86.56 kB / 266.6 MB, free: 9.273 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo): time 0.05795/0.05795, allocations: 14 MB / 328.7 MB, free: 11.07 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 2.321e-05/2.323e-05, allocations: 4 kB / 387.6 MB, free: 68.28 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.06487/0.0649, allocations: 51.12 MB / 438.8 MB, free: 17.18 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.3081/0.3731, allocations: 84.77 MB / 0.5113 GB, free: 9.898 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000182/0.3733, allocations: 72.66 kB / 0.5113 GB, free: 9.891 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBus$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.TestTransformerFixedRatio Notification: Performance of FrontEnd: time 0.01184/0.3852, allocations: 5.584 MB / 0.5168 GB, free: 7.258 MB / 330.7 MB