Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.SynchronousMachine4WindingsPowerSwing.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerGrids.Electrical.Test.SynchronousMachine4WindingsPowerSwing,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100000,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.SynchronousMachine4WindingsPowerSwing") translateModel(PowerGrids.Electrical.Test.SynchronousMachine4WindingsPowerSwing,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100000,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.SynchronousMachine4WindingsPowerSwing") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001042/0.001042, allocations: 174.7 kB / 12.73 MB, free: 2.59 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.263/1.263, allocations: 205.2 MB / 218.5 MB, free: 9.219 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008065/0.0008065, allocations: 89.75 kB / 266.6 MB, free: 9.27 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo): time 0.05951/0.05951, allocations: 14 MB / 328.7 MB, free: 11.06 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 2.294e-05/2.296e-05, allocations: 4 kB / 387.7 MB, free: 68.26 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.06776/0.06779, allocations: 51.11 MB / 438.8 MB, free: 17.17 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.2873/0.3552, allocations: 93.1 MB / 0.5194 GB, free: 3.676 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0001988/0.3554, allocations: 73.72 kB / 0.5195 GB, free: 3.641 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$bus$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.SynchronousMachine4WindingsPowerSwing