Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.OneBusImpedanceOneLoad.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerGrids.Electrical.Test.OneBusImpedanceOneLoad,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.OneBusImpedanceOneLoad") translateModel(PowerGrids.Electrical.Test.OneBusImpedanceOneLoad,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.OneBusImpedanceOneLoad") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00156/0.001561, allocations: 174.7 kB / 12.73 MB, free: 2.59 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.27/1.27, allocations: 205.2 MB / 218.5 MB, free: 9.219 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008743/0.0008744, allocations: 89.75 kB / 266.6 MB, free: 9.27 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo): time 0.05891/0.05891, allocations: 14 MB / 328.7 MB, free: 11.06 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 2.379e-05/2.391e-05, allocations: 4 kB / 387.6 MB, free: 68.28 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.06661/0.06665, allocations: 51.11 MB / 438.8 MB, free: 17.18 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.2791/0.3458, allocations: 82.85 MB / 0.5094 GB, free: 10.36 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000197/0.346, allocations: 73.66 kB / 0.5094 GB, free: 10.35 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBus$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.OneBusImpedanceOneLoad Notification: Performance of FrontEnd: time 0.01679/0.3628, allocations: 7.821 MB / 0.5171 GB, free: 6.977 MB / 330.7 MB