Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Winter.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Winter,tolerance=1e-07,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Winter") translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Winter,tolerance=1e-07,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Winter") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.742/1.742, allocations: 285.4 MB / 298 MB, free: 5.977 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001794/0.001794, allocations: 176.8 kB / 366.4 MB, free: 2.09 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.159/2.159, allocations: 205.1 MB / 0.6248 GB, free: 7.734 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009467/0.0009475, allocations: 100.1 kB / 0.738 GB, free: 40.25 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 4.537e-05/4.546e-05, allocations: 4 kB / 0.8583 GB, free: 13.09 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8943/0.8943, allocations: 115.3 MB / 0.9709 GB, free: 77.89 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 8.349/9.244, allocations: 2.661 GB / 3.632 GB, free: 130.7 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003284/9.244, allocations: 106.2 kB / 3.632 GB, free: 130.6 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Winter Notification: Performance of FrontEnd: time 10.34/19.59, allocations: 2.2 GB / 5.832 GB, free: 64.77 MB / 1.042 GB